Instrument transformers

Low oil oil-paper insulated outdoor current transformers

Voltage range

24-550 kV

Current range

up to 4000 A

Main characteristics:
  • External insulation is represented by both porcelain and polymer insulators
  • Maximum possible number of secondary windings is 7 pcs
  • Precise electric field control and prevention of local partial discharges
  • High operating safety as there are no active parts in the insulator
  • Minimum oil volume through optimized design
  • Easy primary changeover
  • Excellent protection against moisture
  • Installation-friendly terminal box
  • Maintenance free design

Low oil oil-paper insulated outdoor inductive voltage transformers

Voltage range

24-252 kV

Main characteristics:
  • External insulation is represented by both porcelain and polymer insulators
  • Maximum possible number of secondary windings is 5 pcs.
  • Protection of the secondary winding from transient overvoltages in the high-voltage network through capacitively coupled shielding
  • Protection against occurring ferroresonance due to low operating inductance in the iron core
  • Minimum oil volume through optimized design
  • Excellent protection against moisture
  • Easy-to-use terminal box
  • Maintenance free design

Oil-paper insulated outdoor capacitive voltage transformers

Voltage range

24-550 kV

Main characteristics:
  • External insulation is represented by both porcelain and polymer insulators
  • Maximum possible number of secondary windings is 5 pcs.
  • Cost-effective and reliable design for high and very high voltages
  • Expandable for the transmission of high-frequency signals
  • Fabrication-internal adjustment of the accuracy classes, no on-site adjustment is required
  • Temperature- and accuracy stable over the entire service life
  • Increased safety against relaxation oscillation due to damping unit
  • Excellent protection against moisture
  • Easy-to-use terminal box
  • Maintenance free design

SF6 insulated outdoor current transformers

Voltage range

252-550 kV

Current range

up to 5000 A

Main characteristics:
  • External insulation is represented by polymer insulator
  • Maximum possible number of secondary windings is 8 pcs.
  • Low weight and high creepage resistance through the use of composite insulators
  • High flexibility due to simple primary and secondary changeover
  • High operating safety through pressure relief with rupture disc
  • Easy-to-use terminal box
  • Maintenance free design

SF6 insulated outdoor inductive voltage transformers

Voltage range

252-550 kV

Main characteristics:
  • External insulation is represented by polymer insulator
  • Maximum possible number of secondary windings is 5 pcs.
  • Low weight and high creepage resistance through the use of composite insulators
  • High operating safety through pressure relief with rupture disc
  • Easy-to-use terminal box
  • Special iron core provides protection against any ferro resonances
  • Maintenance free design

Resistive capacitive oil-paper insulated voltage divider

Voltage range

72,5-550 kV

Main characteristics:
  • External insulation is represented by polymer insulator
  • Ferroresonance-free and no saturation effects
  • Secondary output can be operated under short-circuit or no-load conditions
  • AC and DC accuracy class ±0.1% at fR
  • Measurement of harmonics possible up to 1 MHz
  • Transient signals can be measured
  • Accuracy with harmonics up to 10 kHz of ±0.2
  • Linear voltage distribution
  • Simple measurement cable connection
  • Maintenance free design

High-amp current transformers

Voltage range

0,72 - 36 kV

Current range

up to 50 000 kA

Main characteristics:
  • Transformers are used for installation in busbar systems of various designs, on generator terminals and in generator circuit breakers

Support type single phase cast resin current transformers

Voltage range

12-72 kV

Current range

up to 4000 A

Main characteristics:
  • Transformers are intended for use in medium voltage grids
  • Maximum possible number of secondary windings is 5 pcs.

Support type single phase cast resin current transformers

Voltage range

12-72 kV

Main characteristics:
  • Transformers are intended for use in medium voltage grids
  • Maximum possible number of secondary windings is 4 pcs.

Modern electrical equipment from leading global and Ukrainian manufacturers

In accordance with the requirements of state and international standards, quality management systems ISO 9001:2015 and environmental management systems ISO 14001:2015